beautypg.com

Haws 2000S User Manual

Page 6

background image

3/14

Model 2000S

Page 6 of 8

Maintenance (continued)

 An instructional label is visible when the hinged panel is opened, noting how to replace the filter

(see below).

o

NOTE: Water does not need to be shut off to replace the filter cartridge; however, it

should be shut off if the filter head is going to be left without a cartridge installed for a
long period of time.

















1. Disconnect the old filter cartridge’s wiring and unscrew the old cartridge.
2. Screw the new cartridge firmly into the filter head and connect the new cartridge’s wiring.
3. The filter status LED should flash green both after the hinged plastic panel is first

closed and when water is dispensing. If it does not, consult the Troubleshooting
Guide.

4. Approximately five gallons of water must be run through the system after the

cartridge is installed in order to remove the loose carbon particles from the filter
cartridge and any air bubbles from the system.

5. Open the unit and examine to assure that there are no leaks; close unit.


Purge Cycle & Cleanliness

 For hygienic purposes, the unit

purges itself briefly if it has not
been used in 24 hours. However, it
is recommended that the drain
basin be regularly cleaned and
disinfected with Clorox

®

Regular

Bleach – use ¾ cup Clorox

®

bleach

and mix in 1 gallon of water. Pour
slowly throughout the drain basin
and let stand for 5 minutes. Flush
with water and let air dry.

o

To access the drain basin

for cleaning, open the
hinged upper panel and
remove the drain grate (see
right).

 The rest of the unit may be cleaned

with a mild sanitizing cleaner, such
as Clorox

®

Anywhere

®

Hard

Surface

TM

Daily Sanitizing Spray.



The Clorox

®

trademark and logo are registered trademarks of the Clorox Company. All rights reserved.

*