current fault

descrIptIon/actIon

dIsplaY

Select Current Fault from the Main Menu and press the Operational

Button under "SELECT" to enter this menu. This menu contains non

adjustable operational information. Use the Up & Down Buttons to

navigate the menu.
This menu contains the current Fault or Alert error message. The

time the Fault or Alert message occurred appears directly below.

A brief description of what causes the particular Fault or Alert

condition appears below that. Pressing the Operational Button

under "ADVANCED" will give more detailed service information and

a list of possible causes for the Fault or Alert condition.
If there is no Fault or Alert condition active this menu will not contain

any information, "(none)" will be shown next to Current Fault in the

Main menu.

CHANGE

BACK

ADVANCED

Blocked Exhaust

Fault occurred 2 mins ago

The exhaust is blocked or

restricted. Ensure

condensate hose is draining.

Call a service professional:

Your Company Name Here

(press [DOWN] for more....)

fault hIstorY

descrIptIon/actIon

dIsplaY

Select Fault History from the Main Menu and press the Operational

Button under "SELECT" to enter this menu. This menu contains non

adjustable operational information. Use the Up & Down Buttons to

navigate the menu.
This menu contains a list of the last nine (9) Fault and Alert messages

with a time stamp. The newest event will replace the oldest.
Press the Operational Button under "VIEW" to view details for each

Fault or Alert message stored.
note: fault history memory is cleared after 30 days.

1:

Blocked Air Intake (A7)

51 mins ago

2:

Blocked Exhaust (A8)

54 mins ago

3:

Low Gas Pressure (A6)

57 mins ago

4:

Blower Prover Failure (AC)

VIEW

BACK

HELP

Fault History

fault occurrence

descrIptIon/actIon

dIsplaY

Select Fault Occurrence from the Main Menu and press the

Operational Button under "SELECT" to enter this menu. This menu

contains non adjustable operational information. Use the Up & Down

Buttons to navigate the menu.
This menu contains a running total of how many times each Fault

condition has occurred since the water heater was first installed.
note: Historical data is stored in the CCB's memory. If this CCB

is replaced during servicing the historical data on the CCB being

replaced will be lost. The data stored in the new circuit board will no

longer reflect the entire history of the water heater.

Ignition Failure

10

ECO

0

Blocked Intake Air

0

Blocked Exhaust

0

Thermostat Input 4

0

Blower Prover

3

Flame Detect Error

0

BACK

HELP

Fault Occurrence

restore factorY defaults

descrIptIon/actIon

dIsplaY

Select Restore Factory Defaults from the Main Menu and press the

Operational Button under "SELECT" to enter this menu.
To restore the adjustable user settings to their factory default

settings press the Operational Button underneath “YES.” The

display will show text confirming the factory default settings have

been restored.
Press the Operational Button underneath “BACK” to exit the Restore

Factory Defaults menu.

YES

NO

Restore Factory Defaults

Are you sure you want to

restore the system to factory

defaults?