Valves for reducing the point-of-use temperature by mixing cold and

hot water are available. Also available are inexpensive devices that

attach to faucets to limit hot water temperatures. Contact a licensed

plumber or the local plumbing authority.
The table below shows the approximate time-to-burn relationship for

normal adult skin. Short repeated heating cycles caused by small hot water

uses can cause temperatures at the point of use to exceed the thermostat

setting by up to 20°F/11°C. If you experience this type of use, you should

consider using lower temperature settings to reduce scald hazards.
In all cases, the following burn table must be used. It’s appearance

may be altered to comply with each manual’s style, but the content

must remain unchanged. NOTE: If the manual is to be used outside

of the United States, metric equivalents (Celsius) must be added to

the table.

Table 11

Water Temperature

°F (°C)

Time for 1st Degree Burn

(Less Severe Burns)

Time for Permanent Burns

2nd & 3rd Degree

(Most Severe Burns)

110 (43.3)

(normal shower temp.)

116 (46.7)

(pain threshold)

116 (46.7)

35 minutes

45 minutes

122 (50)

1 minute

5 minutes

131 (55)

5 seconds

25 seconds

140 (60)

2 seconds

5 seconds

149 (65)

1 second

2 seconds

154 (67.8)

instantaneous

1 second

(U.S. Government Memorandum, C.P.S.C., Peter L. Armstrong, Sept. 15, 1978)

HI LIMIT SWITCH (ECO)
This water heater is equipped with an ECO (energy cut out) non

adjustable high temperature limit switch. The ECO is a normally

closed switch that opens (activates) on a rise in temperature. The

ECO is located inside the Temperature Probe (two red wires). The

ECO switch contacts will open when the water temperature reaches

approximately 202°F (94°C) and close at approximately 140°F (49°C).
If the ECO activates (contacts open) due to abnormally high water

temperatures in the storage tank the control system will immediately

de-energize the 24 VAC Gas Control Valve and end the current

heating cycle. The control system will lock out disabling further

heating operation. The control system will display the Energy Cut

Out (ECO) Fault message on the LCD screen. It is important that

a Qualified Service Technician be contacted to determine the

reason for the ECO activation before resetting the ECO. Once the

reason has been determined and corrected the ECO can be reset

as follows:
Should the ECO activate, the water temperature must drop below

140°F (49°C) before the control system can be reset. Once the water

temperature has cooled below this point the power supply to the water

heater must be turned off and on again to reset the control system.
Contact your dealer or servicer if continued high limit switch operation

occurs.

It is recommended that lower water temperatures be used to avoid

the risk of scalding. It is further recommended, in all cases, that the

water temperatures be set for the lowest temperature which satisfies

your hot water needs. This will also provide the most energy efficient

operation of the water heater.

HOT WATER CAN SCALD: Water heaters are intended to produce

hot water. Water heated to a temperature which will satisfy space

heating, clothes washing, dish washing, and other sanitizing needs

can scald and permanently injure you upon contact. Some people

are more likely to be permanently injured by hot water than others.

These include the elderly, children, the infirm, or physically/mentally

handicapped. If anyone using hot water from this heater fits into one of

these groups or if there is a local code or state law requiring a certain

temperature water at the hot water tap, then you must take special

precautions. In addition to using the lowest possible temperature

setting that satisfies your hot water needs, a means such as a mixing

valve, should be used at the hot water taps used by these people or

at the water heater. Mixing valves are available at plumbing supply

or hardware stores. Follow manufacturer’s instructions for installation

of the valves. Before changing the factory setting on the thermostat,

read the Temperature Regulation section in this manual.
Never allow small children to use a hot water tap, or to draw their own

bath water. Never leave a child or handicapped person unattended

in a bathtub or shower.
SETTING THE WATER HEATER TEMPERATURE AT 120°F/49°C

WILL REDUCE THE RISK OF SCALDS. Some states require settings

at specific lower temperatures.
The water temperature is controlled using the Temperature Control on

the Display at the front of the unit (See “Figure 1B: 50 GALLON UNIT”

& “Figure 1C: 75 GALLON UNIT”). This control utilizes a temperature

probe to determine the tank temperature. The temperature probe is

located behind the heater’s front display.
The temperature may be adjusted from 90°F/32°C to 160°F/71°C. The

temperature was preset to 120°F/49°C before the heater was shipped

from the factory. It is recommended that lower water temperature be

used to avoid the risk of scalding. It is further recommended, in all

cases, that the water temperature be set for the lowest temperature

which satisfies your hot water needs. This will also provide the most

energy efficient operation of the water heater and minimize scale

formation.