7-Calibration
Follow steps 1-7 below to accurately calibrate your readout.
ABS IN
1. RUN A FLAT BOARD 1” THICK OR LESS
THROUGH THE MACHINE MAKING SURE THAT
MATERIAL IS REMOVE FROM THE ENTIRE TOP
SURFACE. DO NOT CHANGE THE SETTING WHEN
DONE.
2. CUT A SMALL
SECTION OF BOARD
TAKING CARE TO
AVOID THE END
WHICH MAY HAVE
SOME SNIPE
IN/MM
ABS/INC
ON/OFF
HOLD TO CAL
0.980
ABS IN
7. REMOVE THE BOARD ALLOWING THE JAWS TO
CLOSE COMPLETELY. TIGTHEN THE LOCK KNOB.
THE DISPLAY SHOWS THE BOARD THICKNESS
AND THE READOUT IS NOW CALIBRATED.
3. LOOSEN
THE LOCK
KNOB
4. LIFT THE SCALE
UPWARDS TO OPEN
THE JAWS. DO NOT
OPEN MORE THAN 1”.
5. PLACE THE CUT PIECE OF
BOARD BETWEEN THE JAWS
AND MAKE SURE THEY CLAMP
FLAT AND TIGHT.
IN/MM
ABS/INC
ON/OFF
HOLD TO CAL
0.000
6. PRESS AND HOLD FOR 3-5 SECONDS
TO SET TO 0.000
ABS IN