Specifications – Outback Power Systems GFX International Series Operators Manual User Manual
Page 54
Specifications
52
900-0112-01-00 Rev B
Table 22
48-Volt Inverter Settings (MATE3)
Field Item Default
Minimum
Maximum
Sensitivity (see page 14 for increments)
6 0 50
Pulse Length
8 4 20
Search
Pulse Spacing
60 AC cycles
4 AC cycles
120 AC cycles
Input Type
Grid
Grid or Gen
Input Support
Y
Y or N
Grid Input AC Limit
25 Aac
2.5 Aac
30 Aac
Gen Input AC Limit
25 Aac
2.5 Aac
30 Aac
AC Input and
Current Limit
Charger AC Limit
5.5 Aac
0 Aac
6 Aac
AC1/Grid Lower Limit
208 Vac
140 Vac
220 Vac
AC1/Grid Upper Limit
252 Vac
250 Vac
280 Vac
Grid AC Input
Voltage Limits
AC1/Grid Transfer Delay
6 AC cycles
0 AC cycles
240 AC cycles
LowerVoltage Limit
208 Vac
140 Vac
220 Vac
Upper Voltage Limit
252 Vac
250 Vac
280 Vac
Transfer Delay
60 AC cycles
0 AC cycles
240 AC cycles
Gen AC Input
Voltage Limits
Connect Delay
0.5 minutes
0.2 minutes
15 minutes
AC Output
AC Output
230 Vac
210 Vac
250 Vac
Cut-Out Voltage
42 Vdc
36 Vdc
48 Vdc
Low Battery
Cut-In Voltage
50 Vdc
40 Vdc
56 Vdc
Absorb Voltage
57.6 Vdc
52 Vdc
64 Vdc
(Absorb) Time
1.0 hours
0.0 hours
24.0 hours
Float Voltage
54.4 Vdc
48 Vdc
60 Vdc
(Float) Time
1.0 hours
0.0 hours
24.0 hours
Battery Charger
Re-Float Voltage
50 Vdc
48 Vdc
26 Vdc
Equalize Voltage
58.4 Vdc
56 Vdc
68 Vdc
Battery Equalize
(Equalize) Time
1.0 hours
0.0 hours
24.0 hours
Aux Mode
Cool Fan
Remote, Load Shed, Gen Alert, Fault, Vent Fan,
Cool Fan, Divert DC, Divert AC, or AC Drop
(Load Shed) Enable Voltage
44 Vdc
40 Vdc
56 Vdc
(Gen Alert) ON Voltage
44 Vdc
40 Vdc
56 Vdc
(Gen Alert ON) Delay
4 minutes
0 minutes
240 minutes
(Gen Alert) OFF Voltage
56 Vdc
48 Vdc
72 Vdc
(Gen Alert OFF) Delay
9 minutes
0 minutes
240 minutes
(Vent Fan) Enable Voltage
52 Vdc
40 Vdc
64 Vdc
(Vent Fan) Off Period
5 minutes
0 minutes
30 minutes
(Divert DC or AC) Enable Voltage
58.4 Vdc
48 Vdc
64 Vdc
Auxiliary
Output
(Divert DC or AC) Off Delay
30 seconds
0 seconds
240 seconds
Inverter
Stacking
Stack Mode
Master
Master, OB Slave L1, 3p Classic B , 3p Classic C
Master Adjust Only
0 0 7
Power Save
Slave Adjust Only
1 1 15
Grid Tie Enable
Y
Y or N
Sell Voltage
47.2 Vdc
40 Vdc
60 Vdc
Grid-Tie Sell
Grid Tie Window
IEEE
IEEE or user
Input Voltage
11
-1 -3 1
Output Voltage
11
-1 -3 1
Calibrate
Battery Voltage
12
0.0 -0.8 0.8
11
These values represent an adjustable setting with a total range of 4 Vac. The default value of -1 means the calibration will subtract 1 volt from the measured
value. The range of settings allow up to 1 volt to be added to the measured value, or up to 3 volts to be subtracted from it. The result is also displayed.
12
These values represent an adjustable setting with a range of ± 0.8 Vdc from the measured value. The range of settings allow up to 0.8 volts to be either added
or subtracted from the measured value (in increments of 0.4 Vdc). The result is also displayed.