beautypg.com

Selling, Operation – Outback Power Systems GFX International Series Operators Manual User Manual

Page 26

background image

Operation

24

900-0112-01-00 Rev B

Selling

IMPORTANT:

Selling power to the utility company requires the authorization of the local
electric jurisdiction. How the local utility company handles this will depend on
their policies on this issue. Some may pay for power sold; others may issue
credit. Some policies may prohibit the use of this mode. Please check with the
utility company and obtain their permission before using this mode.

The GFX inverters are grid-interactive. This means that in addition to using power from the utility grid
for charging and loads, these models can also convert excess battery power and sell it to the utility
grid. This is known as the “grid-tie” or “Sell” feature. Excess battery power usually comes from
renewable energy sources, such as PV arrays, hydroelectric turbines, and wind turbines.

¾ The operation of the Sell feature is referenced heavily in the Battery Charging section, as it is integrally tied

with the battery charger. In fact, selling is occasionally referred to as “charging in reverse”. Where the
charger draws power from the AC input and puts it into the batteries, the Sell feature removes power from
the batteries (or the DC system) and returns it to the AC input.

¾ The Sell feature can only operate while the utility grid power is stable and within certain limits. If the AC

voltage or frequency vary outside these limits, the inverter will stop selling. It may not disconnect from the
utility grid. If the inverter stops selling, the system display will show the reason (page 40 has a list of reasons).

¾ The inverter’s grid-interactive limits are specified on page 46. The AC source acceptance limits are specified

on page 15. These numbers are often not the same.

¾ Once the AC voltage and frequency become acceptable, the inverter has a minimum one-minute delay

before selling will begin. Upon initial connection to the utility grid, the inverter may be required to perform a
full battery charge. This may delay the operation of the sell feature.

¾ In the MATE system display, the key set point is sell re volts. In the MATE3, it is Sell Voltage. (See the system

display manual to change this set point.) When the charger enters the Sell stage (see pages 18 and 19), it
uses sell re volts or Sell Voltage as a reference point. When a renewable source of energy raises the voltage
above this point, the inverter exports power to bring the voltage back down or prevent it from rising further.
The Sell feature only functions when excess DC (renewable) power is available.

∼ The inverter cannot import AC power to raise the voltage to the sell re volts or Sell Voltage set point.
∼ The Sell feature can use other set points than sell re volts or Sell Voltage. If the charger is in a different

stage, such as Absorption or Float, it uses the Absorption or Float voltage as reference points. As long
as the renewable energy exceeds the voltage for that stage, it sells exactly the same as noted above.

¾ When power is returned to the utility grid, it is possible to completely reverse the utility meter. The net result

would be to sell power to the utility company. However, this depends on whether there are other loads in
the system. Loads on the main panel (not on the inverter’s output) may consume this power as fast as it is
generated, preventing the meter from running backwards. In this case, the result of selling would be to
reduce the consumption of AC power, not reverse it.

¾ The maximum amount of power an inverter can sell is not equal to its specified output wattage. It can

exceed the specified wattage under some conditions, usually temporarily. (Its maximum output is 30 amps.)

∼ However, output will vary with inverter temperature, battery type, and other conditions. The inverter

should not be expected to sell 100% of its specified output wattage continuously. Even though it may
be able to do so, this may leave it too hot to perform other functions (such as starting heavy loads if
they are needed during a utility outage).

∼ A good guideline is that the renewable source should be sized to continuously deliver no more than

85% of the inverter’s specified wattage (per inverter, in a multi-inverter system). This recommendation
is specifically for the inverter’s Sell feature. In some cases, the source may be sized larger to account for
environmental conditions or the presence of DC loads. This depends on individual site requirements.