beautypg.com

Protection switching, Rotection, Witching – ADC DL3XR-FCA100 User Manual

Page 12

background image

Front-Panel Description

LTPS-UM-8013-03

4

August 30, 2002

D3LX CO and RMT Modules

P

ROTECTION

S

WITCHING

The D3LX system may be configured for either protected or non-protected mode. For protected mode, two
modules are installed: working and protect. The working module carries the signal, while the protect module is in
standby. Each working module uses 1 group, physically occupying 2 slots. Each protected module occupies an
additional 2 slots; there are four slots required for each D3LX system.

In protected mode, the offline module is switched into service whenever the D3LX determines that a service fault
has occurred in the online module.

Table 1.

D3LX Front-Panel Description and Status LEDs

Name

Function

LEDs

The LEDs can report the following conditions:

Activity

Color

Status

STATUS

Off

Not lit

Blown fuse

On (solid)

Green

Normal operation.

On (solid)

Yellow

Module initializing or performing self test diagnostics or LED test.

On (solid)

Red

Module fault detected.

FAR END

Off

Not lit

Remote alarms inactive (no alarm).

On (solid)

Yellow

Remote alarm on D3LX CO.

DS3 STATUS Off

Not lit

Unequipped.

On (solid)

Green

DS3 active.

On (flashing)

Green

DS3 in loopback, output AIS.

On (solid)

Red

DS3 fault (LOS).

On (flashing)

Red

DS3 in loopback, output AIS.

DS3 ONLINE

Off

Not lit

DS3 offline.

On (solid)

Green

DS3 active.

OPT

Off

Not lit

Optical link active (normal operation).

On (solid)

Yellow

BER fault.

On (solid)

Red

Optical link failure (OOF)

APS

Off

Not lit

No protection switching (normal operation).

On (solid)

Yellow

Force manual protection enabled.

On (solid)

Red

Protection switching limit.

ENABLE
pushbutton

Pressed with APS

In a protected system, the active DS3 are force switched to that module.
Note: The ENABLE pushbutton is pressed first and released last.

Pressed with RESET

Cold start reset (service affecting).
Note: The ENABLE pushbutton is pressed first and released last.

LMPTST/APS
pushbutton

Pressed

Lights front-panel LEDs yellow, except for STATUS and DS3 STATUS which light red.

Pressed with ENABLE

In a protected system, the active DS3 are force switched to that module.
Note: The ENABLE pushbutton is pressed first and released last.

RESET
pushbutton

Pressed

Warm start reset (non-service affecting).

Pressed with ENABLE

Cold start reset (service affecting).
Note: The ENABLE pushbutton is pressed first and released last.

Retaining latch

Secures the D3LX when it is firmly seated in the backplane of the chassis and the latch is in the upright position

This manual is related to the following products: