Troubleshooting

Situation

Indication

Action

Signal LED not lit
Clip LEDs not lit

Check AC plug. Confirm that AC outlet works by plugging
in another device.

Output Current LEDs are lit
Signal LED not lit

Make sure the signal source is operating and try another
cable. Check position of Volume Pots.

Output Current LEDs are lit
Signal LEDs responding to signal level

Check the speaker wiring for breaks.
Try another speaker and cable.

No Sound

Signal LEDs show red (Protect Mode)

Overheating will cause protective muting. Check for
proper ventilation. If the fan isn’t running the amplifier
requires servicing.

No Channel
Separation

No Channel Separation

Check the mode indicators on the front panel and make
sure the mode selector on the rear panel is in the stereo-
position. Make sure other equipment in the signal path
such as mixers and preamps are set for stereo, not mono

Power LED is lit

A faulty speaker or a loose connection could cause this.
Check the wiring and try another speaker.

Signal LEDs responding to signal level

The signal source might be clipping. Keep the volume
pots at least halfway up so that the source does not have
to be overdriven.

Distorted Sound

Clip LEDs not lit

Keep the volume pots at least halfway up and try
changing input sensitivity from 1,4 V to 32 dB or 26 dB
with the gain selector on the rear.

Hiss

Hiss

Unplug the amplifier input to confirm that the hiss is
coming from the source or from a device upstream. Erratic
or popping noises indicate an electronic fault in the
offending unit. To keep the noise floor low, operate the
primary signal source at full level, without clipping. Avoid
boosting the signal further between the source and the
amplifier.

Squeals and
Feedback

Squeals and Feedback

Microphone feedback should be eliminated with mixer
controls. If noise continues to build up with no microphone
gain, there is a serious fault in the signal processors or
cables. Working in succession from the signal source
towards the amplifier and check each device in the signal
path by reducing its gain or by unplugging it.

Comm LED lit

Check connection between computer and any routers or
switched in the network. Reboot computer. If issue is not
resolved, consider replacing CAT-5 Cables

Protea
Communications
Failure

Comm LED not lit

Check connection between amplifier and network. Reboot
computer. If issue is not resolved, consider replacing
CAT-5 Cables