JELD-WEN JII025 Wood/Clad Wood Windows without Exterior Trim or Nailing Fin User Manual
Page 2
INSTALLATION INSTRUCTIONS
for Wood/Clad Wood Windows without Exterior Trim or Nailing Fin (JII025)
2
SAFETY AND HANDLING
SAFETY
• Read and fully understand ALL manufacturers’ instructions before
beginning.
• Do not work alone. Two or more people are required. Use safe
lifting techniques.
• Use caution when handling glass. Broken or cracked glass can cause
serious injury.
• Wear protective gear (e.g. safety glasses, gloves, ear protection, etc.).
• Operate hand/power tools safely and follow manufacturer’s
operating instructions.
• Use caution when working at elevated heights.
MATERIALS AND WINDOW HANDLING
• Make sure operable windows are locked prior to installation.
• Heed material manufacturers’ handling and application instructions.
• Protect adhesive surfaces from dirt, moisture, direct sunlight and
folding over onto themselves.
• Handle in vertical position; do not carry flat or drag on floor.
• Do not put stress on joints, corners or frames.
• Store window in dry, well-ventilated area in vertical, leaning position
to allow air circulation; do not stack horizontally.
• Protect from exposure to direct sunlight during storage.
• Install only into vertical walls and when conditions and sheathing
are dry.
IF INJURY OCCURS, IMMEDIATELY SEEK MEDICAL ATTENTION!
NEEDED MATERIALS AND TOOLS
ROUGH OPENINGS - CONTINUED
NEEDED MATERIALS
Note!
Follow all material manufacturers’ instructions for proper use
and compatibility.
• #8 x 3" corrosion-resistant, pan head screws. Screws must penetrate at
least 1" into framing (or as required by local code)
• Galvanized drip cap (or factory supplied)
• Sealant: We recommend OSI
®
QUAD
®
Max Sealant or equivalent. This
can be used in any application and can be painted or ordered in a
color matched product, if desired.
• Backer rod 1/8" larger than the widest portion of the gap (used in
conjunction with sealant bead).
• Shims – not water degradable or compressible
• Liquid applied flashing (Protecto Wrap LWM 200 or equivalent)
For units rated above DP50:
• Masonry clips
• #8 x 3/4" corrosion-resistant screws for attaching masonry clips to the
window
• #8 corrosion-resistant screws for attaching masonry clips to structure.
Screws must penetrate at least 1" into framing
TOOLS
Open-Stud Wall
• Utility knife
• J-roller
• Hammer
• Tape measure
• Caulking gun
• Level (4' minimum
recommended)
• Construction stapler with 3/8"
staples
• Drill with bits
OPEN-STUD CONSTRUCTION
Wall framing is not covered by
sheathing.