beautypg.com

Roubleshooting, Introduction – Ashland I-175XL2 User Manual

Page 37

background image

T

ROUBLESHOOTING

Introduction

With proper care and maintenance, the I-175XL2 will give many years of reliable service.

When a situation arises where the earthmover performance is not satisfactory, this section

will give some pointers on finding and correcting the problem.

Grease zerk will not take grease.

1. Grease zerk plugged.

a) Remove and replace grease zerk.

2. Pin is frozen.

a) Remove, clean, and inspect pin.

b) Replace pin if necessary.

3. Bushing grease passage is not aligned with grease zerk.

a) Remove, clean, inspect, and realign bushing.

b) Replace bushing if necessary and realign.

Push-off rollers do not roll.

1.

The rollers need lubrication.

a) Check zerk hole and grease.

b) Remove pin, clean, inspect, and replace if necessary.

2. The roller bushing is worn out.

a) Remove roller assembly and replace bushing.

b) See parts manual.

Cylinders will not hold in preset position, i.e. the cylinder creeps.

1. Seals leaking internally.

a) Remove and replace seal kit.