beautypg.com

Ashland I-175XL2 User Manual

Page 36

background image

H

YDRAULIC

S

YSTEM

Standard Two-Circuit Hydraulic Plumbing

The apron cylinders and the push-off cylinder are controlled on the same circuit with

the sequence of the operation controlled by a sequence valve. The other hydraulic

circuit controls the lift cylinders on the earthmover.

*To adjust the sequence valve, see Troubleshooting section.

Optional Three-Circuit Hydraulic Plumbing

The apron cylinders, push-off cylinder, and lift cylinders are all on separate hydraulic

circuits.