H-B Instrument 3760 User Manual

English

background image

Form #0-761

ENGLISH

• Outer sensor high/low temperature alarm setting

• Large display for room/outer sensor temperature

• Maximum/minimum temperature memory

• Room/outer sensor temperature switchable

• °C/°F exchange

• Display backlight

• Foldaway stand

• Velcro fitting

SPECIFICATION

Measuring range

-10 to 50°C/14 to 122°F (zone 1)
-50 to 70°C/-58 to 158°F (zone 2)

Accuracy

±1°C/±1.8°F

Display resolution

0.1°

Display size

48(W)x21(H)mm

Battery

1.5 volt size AAA x 1 piece

Sensor cord length

3 meters

Product size

73(W)x52(H)mm

INSTALLATION

Power On:

Pull down the battery cover and pull out the insulation strip in the battery compartment.

o

Base unit setting: Wipe the desired installation area clean, then remove the protective paper from Velcro
on unit and press the unit firmly to the installation area

o

Outer sensor setting:

Outdoor setting: use the double sided tape to stick the rectangular shape sensor holder to the
desired installation area

Aquarium setting: press the sensor suction cup firmly onto the glass inside the aquarium tank
with a distance of about 100mm under the water level


°C/°F Select:
• Press [°C/°F] button on the back of the unit to select the temperature unit

Room/Outer Sensor Temperature Select:
• Press [In/Out] button to select room or outer sensor temperature. The IN symbol indicates that the reading is for room
temperature and the OUT symbol indicates that the reading is for outer sensor temperature.

Maximum & Minimum Temperature Memory Display:

Press [Max/Min] to display maximum temperature memory (MAX symbol will be displayed)

Press [Max/Min] again to display minimum temperature memory (MIN symbol will be displayed).

Press [Max/Min] again to take instant temperature reading.

Holding [Max/Min] one second to reset minimum and maximum temperature memory.


Display Backlight
• Press [Light] button to turn on the display backlight


High/Low Temperature Alarm Setting (for Outer Sensor only):

Press & hold [Alarm Set] button then the HIGH/OUT icons will flash

Use [°C/°F] button to set the desired alarm high limit

Press [Alarm Set] button once more and the LOW/OUT icon will flash

Use [°C/°F] button to set the desired alarm low limit

Press [Set] again to finish the setting

During the limit setting, holding the [°C/°F] button will advance the value automatically

If the temperature value is out of the set limit, then the alarm will sound

Press any button to stop the alarm sound

Form #0-761

E

o

Press [°C/°F] button on the back of the unit to select the temperature unit

Press [In/Out] button to select room or outer sensor temperature. The IN symbol indicates that the reading is for room

temperature and the OUT symbol indicates that the reading is for outer sensor temperature.

Press [Light] button to turn on the display backlight