10. Connect the black wire that comes from the electrical

service panel (Hot) to the lead or terminal marked LINE.

11. Connect the Traveler wire (usually Red) to the wire or

screw terminal marked TRAVELER. The other end of

this Traveler wire connects to the TRAVELER wire on

the 45610 Auxiliary Switch. The TRAVELER terminal

or lead must be insulated if you are not using it.

See the following section for information about wiring

the 45610 Auxiliary Switch.

12. Insert Z-Wave Switch into the switch box being careful

not to pinch or crush wires.

13. Secure the switch to the box using the supplied screws.
14. Mount the wall plate.
15. Reapply power to the circuit at fuse box or circuit

breaker and test the system.

Note: UL specifies that the tightening torque for the screw

terminals is 14Kgf-cm.

45610 for 3 or 4-Way Control:
1. The 45610 requires the following 3 wiring connections:
a. The Traveler wire. This is used to send voltage signals to

the primary Z-Wave switch. The signals tell the Z-Wave

switch what action to perform.

b. Ground.
c. Neutral.
2. DO NOT connect the 45610 auxiliary switch to the

home’s black Hot (Line) wire.