• Parameter 12 (timing of the steps)
• Length: 1 Byte
• Valid Values:
Parameter 11 (default = 1) Valid Values: 1-99
Parameter 12 (default = 3) Valid Values: 1-255
Ignore Start Level When Receiving Dim Commands
Please note: Every “Dim” command includes a start level
embedded in it. The 45612 can be set to ignore the start level
that is part of the dim command. Setting parameter 5 to a value
of 0 will cause the 45612 to dim or brighten from the start level
embedded in the command.
• Parameter No: 5
• Length: 1 Byte
• Valid Values = 0 or 1 (default 1)
Restoring Factory Defaults
All Configuration Parameters can all be restored to their factory default
settings by using your master controller to delete/reset the device.