Design information, Grounding the appliance – GE ZKD910SFSS User Manual
Page 5
Design Information
5
GROUNDING THE APPLIANCE
Please read carefully.
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY
GROUNDED.
Do not use an extension cord or adapter plug with this
appliance. Follow National electrical codes or prevailing
local codes and ordinances.
This warming drawer must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded branch
circuit, and protected by a 15 or 20 amp circuit breaker or
time delay fuse.
• A properly grounded 3-prong receptacle should be located
within reach of the drawers’ 56” long power cord.
• Locate the receptacle in an adjacent cabinet.
– within 42” of the right side or,
– within 16” of the left side or,
– A recessed receptacle may be located on the right side
of the cutout, 7” from the back of the cabinet. In this
location, the excess power cord should be coiled and
taped to the right side of the unit.
• When two warming drawers are installed side to side, they
can operate from the same receptacle.
Please read carefully.
The power cord of this appliance is equipped with a 3-prong
(grounding) plug that mates with a standard 3-prong
grounding wall receptacle to minimize the possibility
of electric shock. The customer should have the wall
receptacle and circuit checked by a qualified electrician to
make sure the receptacle is properly grounded and has the
correct polarity.
• Where a standard 2-prong wall receptacle is encountered,
it is the personal responsibility and obligation of the
customer to have it replaced with a properly grounded
3-prong wall receptacle.
Do not, under any circumstances, cut or remove the third
(ground) prong from the power cord.
DO NOT USE AN EXTENSION CORD WITH THIS APPLIANCE.
Rating Plate
Recessed
Receptacle
7” Max. From
Rear on Right
Side
Drill 1-1/2” Hole
For Power Cord
For Left or Right
Side Outlet
Location