Design information, Product dimensions – GE ZVC42LSS User Manual
Page 5
5
Design Information
PRODUCT DIMENSIONS
27-1/2"
14"
16-3/4"
25-3/4"
13"
14"
4"
28-1/2"
21-1/4"
1/2"
1-1/4"
7-1/2"
The bottom edge of the insert sleeve has a 7/8"
wide flange on the sides and a 1/2" wide flange on
the front and back.
Remote Location for the Control
The control may be removed from the hood
and installed into a wall or countertop. A 30-ft.
length of wire is supplied to accommodate most
installations. A blanking plate covers the opening
when the controls are removed.
The overall size of the control is 4-1/4" wide and
2-1/4" deep.
We recommend that the cutout in granite or other
hard surfaces be made before the countertop is
installed.
7/8"
1/2"
1/2"
The stainless steel liner is shipped with each hood
insert. This non-combustible liner protects the
underside of the canopy.
Custom Liner
If you are not using the supplied liner, you may
construct a custom non-combustible liner. Use the
supplied liner as a template. The opening must
be 26"W x 13-3/16"D. 3/4"thick material must
surround the opening to allow the sleeve locking
clips to engage. The insert sleeve inside the cabinet
should be positioned 1/2" from the rear wall so
that the center of the 8" duct is 5-1/2" from the
rear wall.
*Opening
ZVC30
The custom canopy must be sized to fit the insert
sleeve. Construct the canopy with an opening
that is:
26"W x 13-3/16"D
The opening must be constructed of 3/4" thick
material to allow the sleeve locking clips to
engage.
The Supplied Liner
Dimensions and Specifications (in inches)
Outside Dimensions
The Insert Sleeve
13"
1-11/16"
3-11/16"
Control cutout
Front side
Front side