Threshold area values, 2threshold area values, Boundaries – HP StorageWorks 8B FC Entry Switch User Manual
Page 22: Alarms
2-10
Fabric Watch User’s Guide
Using Fabric Watch
2
Threshold Area Values
Threshold area values include boundaries and alarms, and apply to all the thresholds within an area.
Changes are stored in the configuration file.
Boundaries
The following boundary information can be modified:
Unit string
Represents unit value. Only the default unit strings are supported by
Fabric Watch.
Time base
Time period within which a specified event is measured. Can be
from one second to one day. Shorter time periods are more sensitive
to fluctuations and therefore will provide more detailed
information.
Note:
The Time base boundary can only be modified through a
telnet command. The Time base bounder does not apply to
the:
- Transmit performance area
- Receive performance area
- Filter class
Low boundary
Minimum value. An event is generated if the element value falls
below this boundary.
High boundary
Maximum value. An event is generated if the element value rises
above this boundary.
Buffer size
Size of buffer set up to decrease generation of in-between events
due to oscillation of the element value over a boundary.
Alarms
The following alarms can be added or deleted:
ERRLOG
Logs errors to switch. If configured properly, sends message to
syslog on daemon.
SNMP-TRAP
Sends trap to SNMP agent.
PORT-LOG-LOCK
Freezes port log to preserve log information generated at time of
event, for diagnostic purposes.
Email Alert
Sends alarm messages to the corresponding mail address.