background image

Fabric Watch User’s Guide

2-3

Using Fabric Watch

2

A profile may contain the following information:

Threshold values:

-

Unit string

-

Time base

-

Lower boundary

-

Upper boundary

-

Buffer size

Alarm values

-

Change

-

Exceed

-

Below

-

Above

-

In-between

-

Behavior type

Classes

Fabric and switch elements are organized into classes (also known as Agents), which are groupings
of closely related elements. The major classes are:

Fabric

Monitors key fabric resources, such as fabric reconfiguration,
zoning changes, new fabric logins

Environmental

Monitors switch environment functions, such as temperature,
power supply, fan status

Port

Monitors port error and performance counters

E_Port

Monitors E_Port error and performance counters

F/FL_Port (Optical)

Monitors optical FL/F_Port error and performance counters

F/FL_Port (Copper)

Monitors copper FL/F_Port error and performance counters

GBIC/SFP

Monitors operational values for FINISAR smart GBICs and SFP
units

ALPA

Monitors ALPA devices of Loop ports (currently CRC error of
ALPA device only).

Note:

The ALPA class is only available if the optional
Performance Monitoring license has been purchased and
turned on.

End-to-End

1 - Monitors transmitting performance predefined by the

SID-DID pair. Configurable with either telnet commands or
Web Tools at run time.

2 - Monitors receiving performance predefined by the SID-DID

pair. Configurable with either telnet commands or Web Tools
at run time.