beautypg.com

6 troubleshooting, Overview, Hp sim integration issues – HP Insight Control User Manual

Page 40

background image

6 Troubleshooting

Overview

This chapter identifies commonly encountered setup and installation problems and provides solutions
for them. The following issues are included:

Insight Control performance management installation and uninstallation issues

Systems Insight Manager integration issues

Licensing and monitoring administration issues

Component issues

Database issues

Windows Server 2003/2008 issues

Internet Explorer issues

Insight Control performance management installation and uninstallation
issues

Table 2 (page 39) describes the solutions to various problems that you might encounter while
installing or uninstalling Insight performance management.

Table 2 Installation and uninstallation issues

Solution

Occurs when

Issue

During remote MSSQL installation,
ensure that the database instance that

Systems Insight Manager and
performance management are
remotely installed on a system.

Incorrect server details retrieved by
performance management.

you specify is not used by any other
performance management application.

HP SIM integration issues

Table 3 (page 39) describes issues and solutions that you might encounter with HP SIM integration.

Table 3 Systems Insight Manager integration

Solution

Occurs when

Issue

Refresh the HP Insight Control console
and click the PF column.

The refresh interval of the Online
Analysis page, which is based on

When the icon in the PF column is
clicked, the overall server performance

sample rates, is different from the

status indicated in Online Analysis

refresh interval of the PF column,

does not match the server performance
status in the PF column.

which is fixed at 2 minutes. As a
result, the performance status
information does not match.

Add the performance management
menu manually.

The PMPTools.xml file is not
executed properly during HP SIM and
performance management integration.

After the Insight Control performance
management installation, the
performance management menu does
not appear on the HP SIM console.

To manually add the performance
management menu, perform either of
the following procedures:

From the command line, enter:
mxtool —a —f ”

installation

path>:\Insight Control

40