Drives – HP ProLiant XL220a Gen8 v2-Server User Manual
Page 29

Hardware options installation 29
CAUTION:
To avoid damage to the drives, memory, and other system components, the air
baffle, and drive blanks must be installed when the server is powered up.
1.
Update the system ROM.
Locate and download the latest ROM version from the HP website
Follow the instructions on the website to update the system ROM.
2.
Power down the server (on page
3.
Disconnect all peripheral cables from the server.
4.
5.
Place the server on a flat, level work surface.
6.
Remove the processor air baffle (on page
7.
Open the DIMM slot latches.
8.
Install the DIMM.
9.
Install the processor air baffle (on page
10.
Install the server into the chassis ("
" on page
11.
Connect all peripheral cables to the server.
12.
Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
If you are installing DIMMs in online spare, mirrored, or lock-step configuration, configure this mode in RBSU
" on page
Drives
The server supports up to four SFF drives (two drives per node).