Redundant hot-plug fans option – HP ProLiant ML370 G5 Server User Manual
Page 59

Hardware options installation 59
14.
Install the access panel (on page
15.
Do one of the following:
o
Close or install the tower bezel, as needed.
o
Slide the server back into the rack.
16.
Power up the server (on page
Redundant hot-plug fans option
The server supports redundant hot-plug fans to provide proper airflow to the system if a primary fan fails.
In the standard, non-redundant, configuration, fans 1, 2, and 3 cool the server.
For the redundant configuration, fans 4, 5, and 6 are added to back up the primary fans. This
configuration enables the server to continue operation in non-redundant mode, if a fan failure occurs. The
following rules apply:
•
If one fan fails in non-redundant mode, the server shuts down.
•
If one fan fails in redundant mode, the server converts to non-redundant mode.
•
If two fans fail in redundant mode, the server shuts down.
WARNING:
To prevent personal injury from hazardous energy:
•
Remove watches, rings, or other metal objects.
•
Use tools with insulated handles.
•
Do not place tools or metal parts on top of batteries.
To install the fans:
1.
Do one of the following:
o
Open or remove the tower bezel, as needed ("
Open or remove the tower bezel
o
Extend the server from the rack (on page
2.
Remove the access panel. ("
3.
Install three hot-plug fans into the center wall.