beautypg.com

English / a-29, Troubleshooting, Machine will not move – Nilfisk-ALTO Captor 4300 User Manual

Page 29: Main broom will not run, Side brooms will not run, Hopper will not raise, Hopper dump door will not open, Shaker motor will not run, Dust control system (impeller) will not run, Scrub system will not run

background image

FORM NO. 56041580 - Captor

4300, 4800, 5400 / CR 1100, 1200, 1400 - A-29

ENGLISH / A-29

TROUBLESHOOTING

If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Nil¿ sk-Advance
Service Center immediately for service.

MACHINE WILL NOT MOVE

Possible causes may be:
1 Parking

Brake

(GG) set (release parking brake)

2

Towing Valve in wrong position (set correctly)

3

Tripped circuit breaker(s) (reset any tripped circuit breakers)

MAIN BROOM WILL NOT RUN

Possible causes may be:
1

Debris wrapped around the broom drive (remove debris)

2

Hopper is not completely down (lower hopper completely)

3

Tripped circuit breaker(s) (reset any tripped circuit breakers)

SIDE BROOMS WILL NOT RUN

Possible causes may be:
1

Debris wrapped around the broom drive (remove debris)

2

Hopper is not completely down (lower hopper completely)

3

Tripped circuit breaker(s) (reset any tripped circuit breakers)

HOPPER WILL NOT RAISE

Possible causes may be:
1

Tripped circuit breaker(s) (reset any tripped circuit breakers)

HOPPER DUMP DOOR WILL NOT OPEN

Possible causes may be:
1

Dump door jammed by debris (remove debris and clean edges of dirt chamber)

2

Tripped circuit breaker(s) (reset any tripped circuit breakers)

SHAKER MOTOR WILL NOT RUN

Possible causes may be:
1

Tripped circuit breaker(s) (reset any tripped circuit breakers)

DUST CONTROL SYSTEM (IMPELLER) WILL NOT RUN

Possible causes may be:
1

Tripped circuit breaker(s) (reset any tripped circuit breakers)

SCRUB SYSTEM WILL NOT RUN

Possible causes may be:
1

Tripped circuit breaker(s) (reset any tripped circuit breakers)

2

Hopper is not completely down (lower hopper completely)

NO DETERGENT FLOW (AXP/EDS)

Possible causes may be:
1

Tripped circuit breaker(s) (reset any tripped circuit breakers)

2

Empty detergent cartidge (¿ ll detergent cartidge)

3

Plugged or kinked detergent À ow line (Purge system, straighten lines to remove any kinks)

4

Dry seal cap on detergent cartidge not sealed (reseat dry seal cap)

5

Detergent ratio slider magnet missing (replace slider)

6

Detergent pump wiring disconnected or backwards (connect or reconnect wiring)

revised 11/07

This manual is related to the following products: