beautypg.com

Alto-Shaam 500-2D User Manual

Page 17

background image

Drawer Warmer Installation/Operation/Service Manual • 15.

Error
Code

Description/Results

PossibleCause
Service Required

E-10

Air Sensor Fault (shorted)

Inoperative Oven

Air sensor is shorted.

Air sensor is defective.

Air sensor is open or has connection failure.

Needair sensor test. See below.

E-11

Air Sensor Fault (open)

Inoperative Oven

E-30

Under temperature

Oven will not reach set temperature

Oven door closed? Door gasket need replacement? Preheat skipped?

Oven overloaded or has frozen product? Defective air sensor or probe?

Defective solidstate relay? Badwire connections or open heating cable?

Is the high limit switch tripped? If none of the above, call service.

E-31

Over temperature

Oven will shut down

Shortedcable? Defective solidstate relay? Defective air sensor?

If none of the above, call service.

E-60

Real time clock error

Inoperative Oven

Appliance has probably been unpluggedfor more than 30 days. If this is the

case, it shouldbe pluggedin with the circuit breaker ON, andthe appliance

displaying the E-60 on the front panel for more than 30 minutes. Once this

has been accomplished, the circuit breaker should be turned OFF, or the

appliance unpluggedfor approximately 10 seconds after which the appliance

shouldbe turnedON again.

E-70

Configuration connector error

Inoperative Oven

Check control connections for loose wires. If none, control must be replaced.

E-78

Voltagelow

Inoperative Oven

If 125 VAC unit, voltage is below 90 VAC. Correct.

If 208-240 VAC voltage is below 190 VAC. Correct.

E-79

Voltagehigh

Inoperative Oven

If 125 VAC unit, voltage is over 130 VAC. Correct.

If 208-240 VAC, voltage is over 250 VAC. Correct.

E-80

EEPROM - Function data error

Inoperative Oven

Replace control.

E-82

EEPROM - Calibration data error

Inoperative Oven

Replace control.

E-84

EEPROM - Unit ID error

Inoperative Oven

Replace control.

E-86

EEPROM - Preset data error

Inoperative Oven

Replace control.

To test air sensor:

Test air sensor by placing sensor in ice water bath andusing an ohmmeter set on the ohm scale.

The reading should be 100 ohms resistance. If it is more than 2 ohms higher or lower, sensor needs

to be replaced.

C A U T I O N

THIS SECTION IS PROVIDED FOR THE ASSISTANCE

OF QUALIFIED SERVICE TECHNICIANS ONLY AND

IS NOT INTENDED FOR USE BY UNTRAINED OR

UNAUTHORIZED SERVICE PERSONNEL.

D A N G E R

DISCONNECT UNIT FROM

POWER SOURCE BEFORE

CLEANING OR SERVICING.

T R O U B L E S H O O T I N G - E L E C T R O N I C C O N T R O L

I N S T A L L A T I O N