- E L E C T R O N I C C O N T R O L

POWER

INDICATOR

LIGHT

UP

/

DOWN

ON

/

OFF

POWER KEY

LOCK INDICATOR

LED DISPLAY

HEAT INDICATOR

LIGHT

ON/OFF KEY

Press the on/off key once and the power indicator light will

illuminate. Press and hold the on/off key until the LED display

turns off (at least three seconds) and on/off indicator goes out.
UP/DOWN ARROW KEY

The up and down arrow keys are used for a variety of settings

when selecting the holding temperature. If an arrow key is pressed

and released the display will show the current set temperature for

two seconds. If an arrow key is held (at least eight seconds), the

value will change at a rapid rate. If the arrow key is pressed and

released in rapid succession, the set temperature will change by

increments of one degree.
ENABLE/DISABLE BEEPER

A beeper sounds when an error code is displayed. To choose

between beeper on and beeper off mode, the control must be

OFF, then press and hold the down arrow key until either "ON"

or "OFF" is shown in the LED display. Release arrow key when

desired mode is displayed.
FAHRENHEIT / CELSIUS

With the control OFF, to choose between Fahrenheit and Celsius,

press and hold the up arrow key until either °F or °C is shown in

the LED display. Release key when desired setting is displayed.
The control has a four-digit LED display. When the display

is ON, it will show current holding temperature, as well as

diagnostic information.

CONTROL LOCK

The warmer controls can be locked so that no changes can be

made to the set temperature.
To lock the display, press and hold the ON/OFF key and the Up

Arrow key at the same time. The lock indicator will illuminate.

When the lock indicator is illuminated, additional programming

will not be functional other than the key sequence required to

unlock the panel.
To unlock the display, press and hold the ON/OFF key and the

Down Arrow key at the same time. The lock indicator will

extinguish. The panel keys will resume normal function.

1. Preheat at 200°F (93°C) for

30 minutes.
Press the ON key, and set the temperature to

200°F (93C°) by using the UP/DOWN arrow

keys. Allow a minimum of 30 minutes

preheating time before loading the drawer

warmer with food. The LED heat indicator

light will go “OUT” after approximately 30

minutes preheat time, or when the air

temperature inside the unit reaches the

temperature set by the operator.

2. Load with pans of hot food only.

The purpose of the warmer is to maintain

hot food at proper serving temperature.

Only hot food should be placed into the

unit. Before loading with food, use a food

thermometer to make certain all products

are at an internal temperature range of 140°

to 160°F (60° to 71°C). Any food product

not within the proper temperature range

should be heated before loading into the

unit.

3. Reset the control to 160°F (71°C).

Check to make certain the drawer is

securely closed, and reset to 160°F (71°C) by

using the UP/DOWN keys.

THIS WILL NOT NECESSARILY BE THE

FINAL SETTING.

The proper temperature range will depend

on the type and quantity of product. When

holding food for prolonged periods, it is

advisable to periodically check the internal

temperature of each item with a food

thermometer to assure maintenance of the

proper temperature range of 140° to 160°F

(60° to 71°C).