Cabling the mds600, Sas cabling guidelines, Cabling guidelines for hp rack and tower servers – HP 600 Modular Disk System User Manual

Page 22: Supported cables

background image

Setup 22

6.

Push the I/O handle up. Be sure the I/O module is fully seated and the I/O module handle is in the
locked position.

CAUTION:

For best cooling practices, do not operate the enclosure for extended periods with

more than one component or blank removed. When removing an active component, replace it
with a blank.

To install the second I/O module, repeat the procedure.

Cabling the MDS600

After installing the MDS600 in a rack, connect the I/O cables and power cords to the rear panel ("

Rear

panel components

" on page

7

).

SAS cabling guidelines

Observe the following guidelines:

Only use supported 2.00 m (6.56 ft) external mini-SAS cables.

Always be sure that the servers attached to the MDS600 are powered down before connecting SAS

cables.

Cabling guidelines for HP rack and tower servers

When directly attaching the MDS600 to HP rack or tower servers, installing a secondary I/O module in the
hard drive drawer is not a valid configuration. See the QuickSpecs on the HP website

(

http://www.hp.com/go/mds600

) for additional special cabling guidelines.

Supported cables

No SAS cables ship with the MDS600. The only supported cable length that can be used is the 2.00 m (6.56
ft) mini-SAS cable.