Interconnect bay overall status icon definitions – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual
Page 211

Hardware information screens 211
•
The module must be physically removed from the bay.
•
The interconnect bay must remain empty for this procedure.
•
The module uplink and downlink ports cannot be in use by networks, uplink sets, or profiles
(including FC profiles) in the enclosure.
•
Port monitoring cannot be enabled on that bay.
VC-FC conditions:
•
The user must have Domain privileges.
•
Physically remove the module from the bay.
•
The interconnect bay must remain empty for this procedure.
•
Change all fabrics on that module to Unassigned for all Virtual Connect profile configurations.
If these conditions are met, click Remove from Domain.
If these conditions are not met, the Remove from Domain button is not available, or an error message is
displayed.
Interconnect Bay Overall Status icon definitions
Icon
Operational state
Meaning
Corrective action
OK
Device is fully operational.
None
Unknown
Device operational state cannot be
determined.
Check Onboard Administrator
communication.
(blue)
Initializing Device
is
initializing. Wait until initialization is complete.
(This icon should only be seen at
startup.)
(yellow)
Degraded
Device is partially operational, but
capability is lost.
Check and correct the Onboard
Administrator error condition.
(orange)
Misconfigured
Device has a configuration error.
Correct the Virtual Connect Manager
configuration attributes.
(orange)
Incompatible
Device does not match the
configuration.
Remove the incorrect hardware. Insert
the correct module.
(orange)
No communication
Cannot communicate with the
device.
Check the physical connections and IP
address.
Missing
Device is configured but not
accessible.
Insert the correct hardware module.
Failed
Device is not operational because
of an error.
Reset the device or application, or
replace the device.
Interconnect Bay OA Reported Status icon definitions
Icon
Operational state
Meaning
Corrective action
OK
Device is fully operational.
None
Unknown
Device operational state cannot be
determined.
Check Onboard Administrator
communication.