Snmp settings (snmp fc settings) – HP Virtual Connect 1.10Gb-F Ethernet Module for c-Class BladeSystem User Manual
Page 185

Domain management 185
SNMP Settings (SNMP FC Settings)
By enabling SNMP for VC-FC modules, network management systems can monitor the VC-FC modules in
the domain for events such as warnings and errors that might require corrective actions. The user must
have network administrator privileges to administer SNMP FC settings.
The VC-FC SNMP settings apply to all VC-FC modules in the VC domain.
The following table describes the fields within the SNMP Settings (SNMP FC Settings) screen.
Field name
Description
Enable SMI-S
Select to enable SMI-S
Enable SNMP
Select to enable SNMP
System Contact
Specify contact name for this system when SNMP is enabled
Read Community
Controls SNMP read access when SNMP is enabled. The default value for read
community string is "public". The read community string must always be set when
SNMP is enabled.
SNMP Alert Destinations
SNMP trap destination table. Maximum number of trap destinations allowed is
five.
After entering an IP address and community string, click Add.
To remove an IP address, highlight the address, and then click Remove.
IP Address
SNMP trap destination IP address