Table 19 RAID Manager Errors Related to Manual Migration Plans (continued)

Required Action

Message

Error Code
(SSB2)

Release the volume from Auto LUN, and then
migrate the volume.

The migration source volume is already specified
as the target volume of Auto LUN.

232F

Perform the following actions, respectively:

Either of the following causes can be considered:

2331

1) Cancel the reservation by Auto LUN, and then
migrate the volume.

1) The migration source volume is already reserved
by Auto LUN.

2) None. This migration plan cannot be executed.

2) The number of slots does not match between
the migration target volume and the migration
source volume.

Reduce the number of pair settings of the specified
volume, and then migrate the volume.

You cannot add pair settings any more to the
volume specified as the migration source.

2332

None. The specified volume is not a source
volume.

The volume specified by the migration cancellation
is not a migration source volume

2333

None. This migration plan cannot be executed.

The emulation type does not match between the
migration target volume and the migration source
volume.

2336

Release the Business Copy pair, and then migrate
the volume.

The migration source volume is a leaf volume of
Business Copy.

2337

Release the Business Copy pair, and then migrate
the volume.

The migration target volume is a primary volume
of Business Copy.

233B

Release the Business Copy pair, and then migrate
the volume.

The migration target volume is a secondary volume
of Business Copy.

233C

Release the volume from Auto LUN, and then
migrate the volume.

The migration target volume is already specified
as the target volume of Auto LUN.

2342

Release the Business Copy pair, and then migrate
the volume.

The migration target volume is set as the primary
volume of Business Copy.

2343

None. The specified volume is not a target volume.

The volume specified by the migration cancellation
is not a migration target volume

2344

Release the Continuous Access Synchronous pair,
and then migrate the volume.

The migration target volume is a primary volume
of Continuous Access Synchronous.

2346

Release the Continuous Access Synchronous pair,
and then migrate the volume.

The migration target volume is a secondary volume
of Continuous Access Synchronous.

2347

Release the volume from Auto LUN, and then
migrate the volume.

The migration target volume is already specified
as the source volume of Auto LUN.

234B

None. This migration plan cannot be deleted or
canceled.

The migration source volume is not paired with
the migration target volume.

2350

None. This migration plan cannot be executed,
deleted, or cancelled.

The migration source volume and the migration
target volume are set to the same volume.

2351

None. This migration plan cannot be executed.

The setting of VLL is different between the migration
target volume and the migration source volume.

2355

Release the Compatible XRC pair, and then
migrate the volume.

The migration source volume is a primary volume
of Compatible XRC.

2362

Release the Compatible XRC pair, and then
migrate the volume.

The migration target volume is a primary volume
of Compatible XRC.

2363

Release the IBM Concurrent Copy pair, and then
migrate the volume.

The migration source volume is a primary volume
of IBM Concurrent Copy (CC).

2365

46

Using RAID Manager for manual Auto LUN

This manual is related to the following products: