Table 19 RAID Manager Errors Related to Manual Migration Plans (continued)

Required Action

Message

Error Code
(SSB2)

The volume cannot be migrated. Check the
configuration definition file

The migration source volume is a quorum disk.

2039

The volume cannot be migrated. Check the
configuration definition file.

The migration source volume is being used by two
mirrors in a 3DC multi-target configuration,

2045

cascade configuration, or delta resync
configuration with three Continuous Access Journal
sites.

The volume cannot be migrated. Check the
configuration definition file.

The migration target volume is being used by two
mirrors in a 3DC multi-target configuration,

2046

cascade configuration, or delta resync
configuration with three Continuous Access Journal
sites.

The volume cannot be migrated. Check the
configuration definition file.

The migration target volume is a quorum disk.

203a

Specify a volume whose capacity is supported.

The current microcode does not support the
capacity of the migration source volume.

204A

Specify a volume whose capacity is supported.

The current microcode does not support the
capacity of the migration source volume.

204B

Release the volume from Continuous Access
Journal, and then migrate the volume.

The migration target volume is being used with
Continuous Access Journal.

2055

Release the volume from Continuous Access
Journal, and then migrate the volume.

The migration source volume is being used with
Continuous Access Journal.

2056

The source volume and target volume cannot
belong to the same parity group. Select a source

The migration target volume and the migration
source volume belong to the same parity group.

2058

volume and target volume from different parity
groups.

Wait for the shredding operation to complete and
then migrate the volume.

The migration source volume is being shredded.

205A

Release the volume from Continuous Access
Journal, and then migrate the volume.

The migration target volume is being used with
Continuous Access Journal.

205C

Perform the following actions for each cause:

The migration source volume corresponds to either
of the following causes:

2075

1.

Change the Snapshot pair status to PAIR, and
then migrate the volume.

1.

The volume is P-VOL of the Snapshot pair. The
pair is not in PAIR status.

2.

None. This migration plan cannot be executed.

2.

The volume is S-VOL of the Snapshot pair or
V-VOL of Snapshot.

Perform the following actions for each cause:

The migration target volume corresponds to either
of the following causes:

2076

1.

Release the Snapshot pair, and then migrate
the volume.

1.

The volume is P-VOL of the Snapshot pair.

2.

2.

None. This migration plan cannot be executed.

The volume is S-VOL of the Snapshot pair or
V-VOL of Snapshot.

Release the pool-VOL setting of Snapshot from the
volume, and then migrate the volume.

The migration source volume is the pool-VOL of
Snapshot.

2078

Release the pool-VOL setting of Snapshot from the
volume, and then migrate the volume.

The migration target volume is the pool-VOL of
Snapshot.

2079

Wait for the quick formatting to complete and then
migrate the volume.

The migration source volume is undergoing quick
formatting.

2089

Troubleshooting when using RAID Manager