Avocent Advanced Console Server ACS 6000 User Manual
Page 34

24 Cyclades ACS 6000 Advanced Console Server Command Reference Guide
8.
Enter
set port_settings/serial_profile=cas
then enter
commit
as shown to assign the CAS
profile and save the settings.
--:- port_settings cli-> set port_settings/ serial_profile=cas
**:- port_settings cli-> commit
--:- port_settings cli->
9.
Enter
set port_settings/status=enabled
, then enter
commit
and
show
as shown to enable the
configured port, save the settings and verify the configuration.
--:- port_settings cli-> set port_settings/ status=enabled
**:- port_settings cli-> commit
--:- port_settings cli-> show
To enable a power management port:
1.
Log onto the CLI as an administrator and enter
cd appliance_settings/ports/physical_ports/
to select a port with a PDU connected (port 3 is used as an example).
--:- Units cli-> cd appliance_settings/ports/physical_ports/
serial_ports/3
2.
Enter
show
to view the configuration of port 3.
--:- 3 cli-> show
3
port_settings/
--:-3 cli->
3.
Enter
cd port_settings
to configure port 3.
--:- 3 cli-> cd port_settings
4.
Type
set
then press
Tab Tab
to view the configuration options.
--:- port_settings cli-> set <
Tab
><
Tab
>
communication_settings port_settings
5.
Enter
show
to view the configuration of port 3.
--:-port_settings cli-> show
port_settings
port: 3
status = disabled
rj45_pin-out = cyclades
serial_profile = unconfigured
communication_settings
speed = 9600
parity = None
data_bits = 8
stop_bits = 1
flow_control = none