beautypg.com

Complete the installation – Bosch HEIP054U User Manual

Page 15

background image

English 12

Three Wire Flexible Conduit Connection

The Four Wire Connection is preferred, but where local
codes and ordinances permit grounding through neutral
and/or conversion to four wire is impractcal, unit may be
connected to the power supply via a three wire connection
1. Disconnect electrical power at the breaker box.
2. Remove the terminal block cover to expose the

terminal block.

3. 3. Remove the top nut, star washer, and round washer

from each post.

Note: DO NOT remove last round washer, last nut or inter-
nal wire leads.
4. Place one terminal lug (packaged with this manual) on

each post. Replace the star washer and round washer
and secure with 20" (50.8 cm) pounds of torque.

5.

Strip 3/8" (9.5 mm) of insulation om the end of each
wire.

6. Insert stripped end of white wire into the center lug on

top of the ground strap. Secure the clam-ping
screw.

7. Insert stripped end of red wire into the left lug. Secure

clamping screw.

8. Insert stripped end of black wire into the right lug.

Secure clamping screw.

9. Tighten each clamping screw with the appropriate

torque (See table below).

10. Properly secure flxible conduit at knockout pa-nel on

range and at supply side junction box. The wiring is
now complete.

Note: DO NOT plug in range at this time.

Complete the installation

Adjust Leveling Legs

1. Make sure circuit breaker is off and then plug range

cord into electrical outlet.

2. Line up range in front of opening.
3. Measure (A) back left corner of opening from floor to

the top of the countertop.

Guage

Torque (in/lbs)

Torque (Nm)

6

35

3.95

8

25

2.82

This manual is related to the following products: