5.
Use the pull-out drain hose located in the pump
access opening to drain the remaining water into a
suitable container (up to 5.3 U.S. gallons/20 liters of
water may be drained). Pull the sealing cap from the
hose and lay the hose over the side of the container
and allow the water to finish draining from the drum.
When finished, replace the sealing cap into the end of
the hose and restore the hose to its storage location.
6.
Turn the pump cover counterclockwise to remove it. A
small amount of residual water may flow out when the
cover is removed.
Clean the interior of the pump housing, removing any
debris or foreign objects. Check to be sure the
impeller wheel at the back of the pump housing can
now turn freely.
Remove any lint, debris or detergent residue from the
threads of the pump cover and the pump cover
housing.
Replace the pump cover and tighten the screws.
Handle must be vertical.
7.
Screw the protective film on the pump on again.
8.
Insert the service cover snap it in, and close it.
NOTICE: In order to prevent detergent from flowing
unused into the drain during the next wash cycles: pour
0.26 U.S. gallons/1 liter water into the chamber II.
Turn the cycle selector to the Spin/Drain cycle, select No
spin and press the Start/Pause button.