7

Maximum gap to

cabinet back allowed

before installation of a

wood support is

required for mounting

stabilizing brackets

9-5/8”

(24.5 cm)

Countertop

Cooktop

Downdraft

Top Trim

Chassis

Housing

Transition

Duct

4-1/2”

(11.4 cm)

Basic Information

A qualified technician must complete the installation

of this appliance. This downdraft blower system is

designed to be used to exhaust airborne contaminants

when cooking with a variety of gas, electric or

induction cooktops.
It can be mounted in island, peninsula, or conventional

wall locations.
This unit is installed following these basic steps:
• Cut out the countertop opening.

• Mount the unit in the cabinet.

• Connect the ductwork and electrical.

• Install the cooktop.

Take Measurements

Refer to the cooktop installation instructions for

dimensions of the cooktop, countertop cut-out

and cabinet requirements. It is recommended that

oversized cabinets be used for easier installation.
Cooktop depth can vary greatly from one unit to

another. This may cause the fit of the cooktop and

the telescopic downdraft appliances to be tight in the

countertop depending upon the overall depth of the

countertop.

Typical Installation

Countertop

Cooktop

Front to back

Inside cabinet depth

2

5

/

16

(5.8 cm)

1

/

8

(0.3 cm)

Countertop

A

B

Cooktop

Chassis

Housing

Chassis

Housing

Front to back

Inside cabinet depth

2

5

/

16

(5.8 cm)

2

1

/

16

(5.2 cm)

2

1

/

16

(5.2 cm)

1

/

8

(0.3 cm)

1

/

4

Min.

(0.6 cm)

The high level of air flow of this appliance may

affect the gas flame on some gas cooktop models.

Extreme caution must be used to assure proper

flame is generated and maintained through the

operating range of the vent. Refer to cooktop

Installation Instructions and Use and Care guide for

proper gas burner setup. Gas cooktop installation

and service must be performed by a qualified

installer, service agency or gas supplier.

1

/

4

” Min.

(0.6 cm)

clearance

behind

downdraft

NOTE

Preformed countertops with a raised lip and/or

backsplash as illustrated in (A) or (B) may not

allow enough flat countertop for proper installation.

Note that a minimum of 2 5/16” of flat countertop is

required behind cooktop and that 2 1/16” is necessary

between the back edge of the cooktop and the inside

of cabinet back.

Planning