• If the de-energizing time is incorrect:

• Adjust the “time adjust” on the stop motion detector module and retest.

If the input #0, 10 on the PLC (Programmable Logic Controller) is not on after several rotations
of the tumbler (basket):

• Check fuse #2 and replace if necessary.

• Rotate the tumbler (basket) using the pendant control in ”LOAD POSITION.” Does the

module’s L.E.D. (light emitting diode) respond?

• If yes, adjust the “sense time” until the L.E.D. (light emitting diode) stays on for 12 to 15

seconds after the tumbler (basket) stops, then refer to Section 7a on page 72.

• If no, check:

• Inductive proximity sensor for damage.

• Sensor distance from targets is 3/16”. The proximity sensor is located in the same area as

the tumbler junction box.

• Inductive proximity adjustment.

• Tumbler (basket) target.

• Stop motion detector module.

• Circuit wiring;

Refer to the dryer’s Main Panel Wiring Diagram, dryer’s Tumbler Junction Box Wiring
Diagram.