• If no voltage is measured;

• Start a drying cycle, and monitor the voltages on TB1-23 and 9.

• If a voltage is present during drying start-up, the switch is functioning.

• If a voltage is not present while the dryer is started, check:

• Air Switch Adjustment.

• Switch.

• Circuitry (dryer Main Wiring Diagram and dryer Solenoid Junction Box Wiring Diagram).

3b) To check the electrical actuating of the pilot gas valve.

• Shut the main gas valve to the dryer.

• Open the disconnect block on TB1-63, for circuit testing. With control voltage “ON”, apply a

100 VAC line to TB1-63. THE PILOT GAS VALVE SOLENOID SHOULD ACTIVATE.

• If the solenoid does not cycle check circuitry; dryer Main Wiring Diagram, and dryer

Solenoid Junction Box Wiring Diagram.

• Check gas valve solenoid.

• Retest.

• With the main gas valve OPEN, close disconnect block on TB1-63 and Measure for 110 VAC on

TB1-63 and TB1-9 on the Main Electrical Panel during a drying cycle start-up.

• If a 110 VAC is present during start-up, burner pilot output circuit is OK.

• If a 110 VAC is not present;

• Check circuitry; refer to dryer Main Panel Wiring Diagram and dryer Solenoid Junction

Box Wiring Diagram).

• Refer to Section VI, Part D, Gas Burner and Ignition System on page 37 thru page 45.

4b) To check the electrical actuation of the Ignition Transformer;

• Shut the main gas valve to the dryer.

• Open the disconnect block on TB1-65, for circuit testing with control voltage “ON”, apply a

110 VAC line to TB1-65 “output” ARCHING SHOULD OCCUR AT THE SPARK IGNITER
IN THE BURNER ASSEMBLY.

• If there is arcing, close disconnect on TB1-65.