beautypg.com

American Dryer Corp. MLG-460 User Manual

Page 51

background image

47

S

AFETY

D

EVICES

L

OCATION

F

UNCTION

C

OMPUTER

D

ISPLAY

M

ESSAGE

R

ESULT OF

TRIPPING

Load Door Switch

Left side of load door

Insures dryer load doors

are closed

"DOOR OPEN"

Dryer will not run

Unload Door Switch

(2-Door Dryers Only)

Right side of unload door

Insures dryer unload

door are closed

"DOOR OPEN"

Dryer will not run

Tilting Switches

Top left side of base

module

Insures dryer is level

"LEVEL FAULT"

Dryer will not run

Drum Rotation Sensor

Left side of tumbler

section

Insures tumbler is

rotating

"DRUM FAULT"

Stops heat only

Lint Chamber Air

Pressure Switch

Center of heat console

Insures proper air flow

through dryer

"AIRFLOW FAULT"

Stops heat only

Burner Fan Air Flow

Switch

(Gas Dryers Only)

Center of heat console

Insures proper

combustion air flow into

the burner box

"HEATER FAULT"

Stops heat only

Hi/Lo Gas Pressure

Switch

(Gas Dryers Only)

Lower left of heat

console section

Insures proper gas supply

pressure for adequate

ignition

"GAS SUPPLY

FAULT"

Stops heat only

Heat Reclaimer Damper

Switch

Right side of heat

console

Insures that the heat

reclaimer is either opened

or closed

Input LED #13 of the

PLC is off

None

Heat Console Door

Access Door Switch

Inside heat console

Insures that access doors

are closed

"DOOR OPEN"

Dryer will not run

Exhaust Air Temp

Control Sensor

Inside burner section

duct

Monitors tumbler exhaust

air temp

"EXHAUST DSFL"

Stops heat only

Exhaust Air Hi Temp

Control Sensor

Inside exhaust duct

Monitors tumbler

exhaust

and air temp

"HI-TEMP FAULT"

Stops heat only

Intake Air Temp Control

Sensor (optional)

Top right of tumbler

seection

Monitors tumbler air

intake temp

"INTAKE DSFL"

Stops heat only

Intake Air Temp Control

Sensor

Top right of tumbler

section

Monitors tumbler air

intake temp

"HI-TEMP FAULT"

Stops heat only

Burner Hi-Limit Safety

Sensor

Top of burner section

Monitors air temp above

the burner box

"HI-TEMP FAULT"

Stops heat only

Sprinkler Control Safety

Sensor

Top right of tumbler

section

Open sprinkler system

water valve on hi-temp

condition

Orange sprinkler pilot

light comes on. Alarm

sounds

Opens the sprinkler

water valve and

power down the

whole dryer

Lint Drawer Switches

Above lint drawer

handles

Disables machine when

drawers are open or if
drawers have not been

cleaned in last five loads

Lint Drawer

Dryer will not run