Canon LV-8320 User Manual
Page 17
LV-8320 Basic Serial Command Specifications
-14-
6.34. IMAGE (Toggle) Command
Command “C27”[CR]
Detail
Switch Image Setting status.
This command works the same way as “IMAGE” button of the remote control.
Response
Acceptable [ACK]
[CR]
Unacceptable “?”[CR]
6.35. Direct on Setting Command
Command “C28”
[CR]
Detail
Enable Direct power on function.
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Response
Acceptable [ACK]
[CR]
Unacceptable “?”[CR]
6.36. Direct on Cancel Command
Command “C29”
[CR]
Detail
Cancel Direct power on function.
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Response
Acceptable [ACK]
[CR]
Unacceptable “?”[CR]
6.37. Power Management Ready Command
Command “C2A”
[CR]
Detail
Set Power management mode to Standby mode.
This status is stored in EEPROM and retained regardless of Power ON/OFF.
Response
Acceptable [ACK]
[CR]
Unacceptable “?”[CR]
6.38. Power Management OFF Command
Command “C2B”
[CR]
Detail
Set Power management mode to OFF mode.
This status is stored in EEPROM and retained regardless of Power ON/OFF.
Response
Acceptable [ACK]
[CR]
Unacceptable “?”[CR]
6.39. Power Management Shut down Command
Command “C2E”
[CR]
Detail
Set Power management mode to Exit mode.
This status is stored in EEPROM and retained regardless of Power OFF/ON.
Response
Acceptable [ACK]
[CR]
Unacceptable “?”[CR]