Typical pier type installation cutout dimensions – American Standard Williamsburg 2806E User Manual
Page 2
UNLESS AN ACCESS OPENING OF AT LEAST
12" X 24" (305 X 610MM) IS PROVIDED,
WARRANTY SERVICE WILL NOT BE PERFORMED.
752872-100 REV. C (2)
INSTALLATION AND FRAMING INSTRUCTIONS
The variety of installations possible for this whirlpool may require framing procedures other than those shown. Locate studs
as required. Ensure roughing-in dimensions are proper, plumb and square. Provisions must be made in all installations for an
access opening for servicing the pump and controls. It is strongly recommended that an additional opening be provided for
access to the drain components.
NOTE: The apron should not be used as the primary access opening.
1. Position the whirlpool into the installation opening and level the deck, shimming the integral support feet as necessary.
2. Install drain components to the whirlpool following the manufacturers instructions. Before replacing your whirlpool for final
installation, be certain that an opening has been provided in the sub-floor for the drain. See the roughing-in drawing for
suggested opening size and location dimensions.
3. Replace whirlpool and re-shim the integral support feet, shimming the entire length of the support feet. Secure the shims
using construction adhesive, silicone, mortar or equivalent materials. While not a necessity, the use of a foundation base
consisting of cement (e.g. Sakrete), mortar, or grout will help provide a solid and secure installation.
TYPICAL PIER TYPE
INSTALLATION
CUTOUT
DIMENSIONS
*
S E E C U T O U T T E M P L A T E P R O V I D E D
1 9 - 1 / 2
( 4 9 5 m m )
2 4
( 6 1 0 m m )
12
(305mm)
*
*
A S
D E
S I R
E D
A S D E S I R E D
451mm
(17-3/4) R.
MINIMUM DIMENSION
FOR FACE TO FACE
OF SUBSTRUCTURE
*
435mm
(17-1/8) R.
*
870mm
(34-1/4)
*
1784mm
(70-1/4)
*
889mm
(35)
*
749mm
(29-1/2)
TYP.
*
10mm
(3/8)
DRAIN END OF
WHIRLPOOL