American Standard Cadet Elite 6' x 36 2773E Series User Manual
Installation instructions, Whirlpool/bathing pool 2773e series, Cadet elite™ 6' x 36
752862-100 Rev. D
© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
T H A N K Y O U . . .
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
• Flex-Jet Pulse Jet Kit*
• Flex-Jet Soft Jet Kit*
• E-Z-Install Heater*
• Tile Bead Kit*
• Apron Kit*
List of Required Components (not included):
• Drain* • Bath Filler*
* see your Home Depot Retailer
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 2
Stringers
• Drop Cloth
• 20 amp GFI
Outlet
• Cement, Plaster,
Grout
INSTALLATION INSTRUCTIONS
HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS
CADET ELITE™
6' x 36"
WHIRLPOOL/BATHING POOL
2773E SERIES
RECOMMENDED FITTING LOCATION
64 X 330mm (2-1/2 x 13")
FOR PIER OR ISLAND
INSTALLATIONS ONLY
ALT. FITTING
LOCATION #1
1829 mm
(72)
908 mm
(35-3/4)
OUTLINE OF CUTOUT
1791 mm x 870 mm
(70-1/2 X 34-1/4)
454 mm
(17-7/8)
464 mm
(18-1/4)
38 mm
(1-1/2)
502 mm
(19-3/4)
1-1/2 O.D.TAILPIECE
■
LEVELING STRINGER
NOT FOR SUPPORT
ROUGH
FLOOR
229mm
(9)
305 mm
(12)
57mm
(2-1/4)
(8) JETS
70mm
(2-3/4)
CUTOUT IN FLOOR
FOR DRAIN
PUMP
FINISHED
WALL
305mm
(12)
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
1651 & 1981mm
(65 & 78)
C/L OF
OVERFLOW
102 mm
(4)
C/L OF
SPOUT
C/L OF
VALVES
C/L OF
SHOWER ARM
70 mm
(2-3/4)
117 mm
(4-5/8)
1-1/2 N.P.T.M.
THREADS
19 mm
(3/4)
229 mm
(9)
C/L OF
SUPPLIES
C/L OF DRAIN
SEE FITTING
SPECS FOR
DIMENSIONS
(2) AIR VALVES
ON/OFF
SWITCH
PROVIDE ACCESS TO PUMP FOR
SERVICING ON ALL INSTALLATIONS
INTEGRAL
SUPPORT
FEET
IN-LINE HEATER
REMOVABLE
BLANK
72 x 35-3/4 x 19-3/4 In.
(1829mm x 908 mm x 502mm)
101 Lbs. (45 Kg.)
751 Lbs. (341 Kg)
78 Gal. (295 L.)
64 Gal. (242 L.)
23 x 49 In. (584 mm x 1245 mm)
65 x 29 In. (1651 x 737 mm)
13-1/2 In. (343mm)
40 Lbs./Sq. Ft. (190 Kgs/Sq. m.)
23.8
48.3
GENERAL SPECIFICATIONS FOR 2773E WHIRLPOOL
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
MIN. OPERATING GAL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)
WHIRLPOOL ELECTRICAL SPECIFICATIONS
2.1 HP, 14.4 AMPS, 120V.
PUMP