Wiring connectors – Ultra Start 600 User Manual
Page 5

Installation Guide
WIRING CONNECTORS
Pink
Channel 4 Output
Programmable - See menu 2, setting 5.
Green
(-) Door Input
Negative door pin switch input.
Blue
(-) Hood Input
Negative input from hood pin switch.
Purple
(+) Door Input
Positive door pin switch input.
Brown
(+) Siren Output
Positive output for siren.
White
(+) Park lights
Park light output. Programmable - menu 2, setting 3.
Blk/White
(+/-) Dome Light
Dome light supervision. See page 5.
Blk/White
(+/-) Dome Light
Dome light supervision. See page 5.
Orange
(-) When Armed
Negative output when system is armed.
Grey
(-) Trunk Release
Negative output for trunk release. 500ma max.
Yellow
Ignition Input
Input from vehicles ignition wire.
Black
Ground Input
System ground input.
Red
Main Power Input
Constant 12 Volt input.
14 Pin Connector
Green
Door Lock
Door Lock Output - Programmable - menu 1, setting 3.
Red
12 Volt Output
Output for voltage inverter.
Blue
Door Unlock
Door Unlock Output - Programmable - menu 1, setting 3.
Low Current Only
Pink
Second Unlock Second Unlock Output - Programmable - menu 1, setting 3
4 Pin Connector Red
2 Pin Connector Blue
2 Pin Connector Red
3 Pin Connector White
4 Pin Connector White
Second 4 Pin Connector White
Plug-in Program Button Connector.
The program Button is used to access the systems Programming Menu’s.
See page 5. for installation instructions.
Plug-in LED Connector.
See page 5. for installation instructions.
5
Green
(-) When Disarmed
Negative output when disarmed.
Pink
Horn / Channel 5.
Programmable - See menu 2, setting 7
Blue
(+) Disconnect
Triggers when 12volt circuit is broken.
Blue
Sensor Full Warn
Input trigger for addition alarm sensor(s)
Green
Sensor Pre Warn
Input trigger for addition alarm sensor(s)
Black Ground
Output
Ground output for addition alarm sensor(s)
Red
12 Volt Output
12 volt output for additional alarm sensor(s)
Satellite link connector.