Operation, Specifications – Timeguard DSS User Manual
Page 14
13
14
4. Operation.
Whenever light or appliance operation is required press the push
button and the light(s)/appliance(s) under control will remain ON
for the set delay time.
5. Specifications.
i Conforms to Directives: 73/23/EEC & 89/336/EEC
ii Permissible Loads:
Filament lamps – 1.5kW
Low voltage – 20 to 200W
Heating – 2kW
Inductive – 4A
Motor – 1hp
Not suitable for fluorescent or low energy lighting.
iii Operating Ambient
Temperature Range:
-10°C to 40°C
iv Operating Voltage:
220 to 240V 50Hz
V Delay Time:
4 ranges selectable by tamperproof
two gang switch:-
3 sec. to 30 sec. (nominal)
12 sec. to 2 min. 4 sec. (nominal)
1 min. 36 sec. to 16 min. 31 sec. (nominal)
12 min. 26 sec. to 2hrs. 12 min. (nominal)
All adjustable by tamperproof
potentiometer (nominal times
vary by up to ±25%)
vi Terminations:
Suitable for 1mm
2
and 1.5mm
2
solid
conductors and stranded equivalents
vii Minimum Box Depth: 16mm
viii Standby Consumption: Less than 2 VA