15 Programming Across Midnight

This can be achieved by programming the required ON time in the initial day and the

required OFF time in the subsequent day. The unused times in these two programmes

can either be left blank (--:--) or used for an OFF time during the initial day and an

ON time during the subsequent day.

16 Self Cancelling Override

To change the output status from ON to OFF or vice versa press the button.

The output status will change and indicate override is in operation by flashing either the

ON or OFF symbol on the display. The override will end at the next programmed change,

or sooner, if the button is pressed again.

17 Random Operation

By pressing the for around three seconds whilst in normal operating mode a small

R appears on the display. The unit will now switch ON and OFF in a random fashion during

programmed ON periods in both AUTO and AUTO & PHOTOCELL modes. Both the ON and the OFF

periods will vary in a random way between 10 and 31 minutes. Normal switching can be restored

by pressing the button for around three seconds until the R symbol reappears.

Specifications

i Conforms to Directives: 73/23/EEC & 89/336/EEC.

ii Permissible Loads:

Filament 40 – 300W

Low energy 20 – 150W (electronic & iron ballast)

Fluorescent 18 – 76W

Low voltage 20 – 200W

iii Battery Back-up:

1000 hours by factory fitted rechargeable battery.

iv Operating Ambient

Temperature Range:

-10°C to 40°C.

v Operating Voltage:

220 – 240V AC.

vi Dusk Start:

1-5 Lux

vii Terminations:

Suitable for 1mm

2

and 1.5mm

2

solid conductors

and stranded equivalents.

viii Control Type:

1Y

Not suitable for discharge lighting (e.g. SON and Metal Halide) and

LED lights. The unit will fit in a 16mm deep box.