Technical data

Nominal voltage:

220 –240 V~, +10 %/-15 %

Frequency:

50–60 Hz

Brightness range:

2–2.000 lx

On/off switch delay:

0–59 min

Power consumption:

type 3 VA

Switching output:

phase-independent

(zero-crossover switching)

Contact:

two way switch

Contact material:

AgSnO

2

Switching capacity:

16 A/250 V~ cos

ϕ = 1

10 A/250 V~ cos

ϕ = 0,6

Fluorescent lamps:

10 AX

Switching capacity min.: 10 mA/230 V AC

100 mA/12 V AC/DC

Glow lamp load:

2600 W

Halogen lamp load:

2600 W

Fluorescent lamps (VVG – low-loss series devices):

uncorrected:

2300 VA

series-corrected:

2300 VA

parallel-corrected:

800 VA (80µF)

Lead-lag circuit (duo): 2300 VA

Fluorescent lamps (EVG – Electronic series devices):

650 VA

Mercury and sodium vapour lamps:

parallel-corrected:

800 VA (80µF)

Compact fluorescent tubes (EVG): 22x7 W, 18x11 W, 16x15 W,

16x20 W, 14x23 W

Permissible ambient temperature: –30 °C ... +55 °C (device)

–40 °C ... +70 °C (sensor)

Protection class:

II (light sensors III) in

accordance with EN

60730-1 if correctly

Protection rating:

IP 20, IP 55 (Mounted

light sensor),

IP 65 (Installation light

sensor) in accordance

with EN 60529