Technical data – Timeguard TR 608 top2 User Manual
Page 23
23
GB
Technical data
• Operating voltage:
230 –240 V~, +10 %/-15 %
• Frequency:
50–60 Hz
• Power consumption:
ca. 0,4 W
• Standby min.:
ca. 0,4 W
• Switch output:
switching of choice of
external wires is permitted
• Contact:
two way switch
• Gap:
<3 mm (µ)
• Contact material:
AgSnO
2
• Max switching capacity: 16 A, 250 V~, cos ϕ = 1;
4 A, 250 V~, cos ϕ = 0,6
• Min. switching capacity: 10 mA/230 V AC
100 mA/12 V AC/DC
• Incandescent lamp load: 1000 W
• Halogen lamp load:
1000 W
• Fluorescent lamp load: uncorrected,
series corrected 1000 VA
parallel correction 120 W (18µF)
• Compact fluorescent lamps: 40 W
• LED lamps:
<2 W output, max. connec-
tion total of 10 W,
>2 W < 8 W output, max.
connection total of 25 W
• Permissible ambient temperature:
–25 °C ... +55 °C
• Protection class:
II in accordance with
EN 60730-1 subject to
designated installation
• Protection rating: IP 20 nach EN 60529
• Time accuracy:
≤ ±0,5 s/day at 25 °C
• Power reserve:
10 years (lithium cell)
at +20 °C
• Pollution degree:
2
• Rated impulse withstand voltage: 4 kV
• Max. switching cycles with 16 A
resistive load:
50,000