F e a t u r e s
Inverter Features
The TruePower inverter comes standard with a Ground Fault Circuit Interrupter
(GFCI) protected Dual AC outlet which can protect the user against hazardous
electrical shock that could be caused by dampness, water spray, or worn cables.
Bat’ Saver- mode allows the user to protect from draining down the entire power of
the engine start battery, and shuts the inverter off when the battery reaches a threshold
of 11.7 volts allowing you to still start your boat or vehicle.
Soft Start, Noise Filtered Technology- progressively increases the output voltage to
start heavy loads, with minimal or no interference.
Optional Standard Function Remote- can be purchased as an accessory and may be
plugged into the remote prot for the 600w thru 1200w models.
TruePower performance features include:
- Internal Conformal Coating for Anti-Corrosion
- Soft Start and Noise Filtered Technology
- Bat’ Saver Mode – 200 to 1200 watt Models
- True Rated Continuous Power
- Hi-Surge Ratings for Demanding Loads
- Heavy Duty Marine/Industrial Construction
- Constructed to UL 458
- Meets the Requirements of ABYC E-11 Marine
- Highly Visible Power & Fault LED Indicators
TruePower Inverters are protected by a variety of features including:
- GFCI AC Outlet Safety Protected
- Input Polarity Protection
- Low Battery Alarm
- Low Battery Shutdown
- Overload Protection
- Output Short Circuit Protection
- Thermal Protection
- Over Voltage (15 VDC) Protection
Note: These inverters may not be suitable for use with some fluorescent lighting,
halogen lights or other inductive loads. If you wish to run such an item, plug it in
to one of the inverter outlets and plug in a small non-inductive load bearing item
such as a low wattage light bulb into the other outlet.
5
14
Tr o u b l e s h o o t i n g
No AC output voltage. Red Fault LED light is illuminated.
Possible Cause:
- Inverter may be overloaded.
Solution:
- Disconnect all appliances connected to the inverter and reset the inverter by
turning the ON/Off switch to Off then back to ON.
Possible Cause:
- Battery voltage may be too high.
Solution:
-The inverter will restart if the battery voltage drops below 15.5 volts DC.
Possible Cause:
- Battery voltage may be too low.
Solution:
- Battery voltage becoming low, recharge battery and resume inverting power.
Possible Cause:
- Over temperature.
Solution:
- Allow the inverter to cool down. The inverter will start automatically.
Possible Cause:
- Unit may be defective
Solution:
- Call Factory Service 800 number.
No AC output voltage. NO Lights are illuminated.
Possible Cause:
- Battery voltage is too low.
Solution:
- Recharge the batteries. Restart the inverter with recharged batteries.
Possible Cause:
- Poor DC wiring.
Solution:
- Turn the inverter to Off. Disconnect the DC wiring. Use proper wiring and ensure
all connections are secure.