4

O v e r v i e w

1

TruePower Overview

The above picture outlines the front of the TruePower Inverter with bullets pointing
out digital bar graph display, on/off and bat’ saver, led locations etc. Please Reference
Table below for features:

1. ON/Off Switch turns the inverter to ON, OFF or to Bat’ Saver mode
2. Power light illuminates when inverter is on.
3. Fault Light illuminates Red for fault conditions such as over temperature, output
overload, or battery low voltage.
4. Two GFCI Protected AC Outputs to power connected appliances, Reset and Test
monthly capabilities.
5. Ventilation Openings provide air circulation for peak performance. (front and rear panel)
6. Remote Port for optional simple remote with on / off switch and power and fault led

The above picture outlines the back of the TruePower Inverter with bullets pointing out
DC connections, fuse holder locations etc. The Table below references the above
numbered features of the back panel

7. DC Input Cable (Positive +)
8. DC Input Cable (Negative -)
9. Fan Housings
10. Ground Stud
11. Mounting flanges (Side)
12. Tech Spec Label

2

3

4

5

6

8

10

7

12

9

11

Fan does not turn on.

Possible Cause:
- The power rating of the appliance may be too low or the ambient temperature
is too cool.

Solution:
- No action. The fan will run at full speed when the inverter is powering a higher
rated appliance.

Fan runs all the time.

Possible Cause:
- The power rating of the appliance is too high.

Solution:
- No action. The fan will run at full speed when the inverter is powering a higher
rated appliance.

Possible Cause:
- The ambient temperature is high.

Solution:
- No action. The fan will run at a higher ambient temperature to keep the
inverter cool.

Low Battery alarm sounds continuously

Possible Cause:
- Bad wiring or connection

Solution:
- Tighten and clean all DC connections

Power tool will not start

Possible Cause:
- Large start-up (surge) current demand.

Solution:
- If power tool will not start, then proper sized inverter should be used.

15

Tr o u b l e s h o o t i n g

Fault

Power

GFCI 110 VAC Output

Remote Port

Bat-Sav'r

On Board

Solutions

A ProMariner Company

Off

On

AMPS

VOLTS

12

13

14

15

0

25

50

100%

75

10

POS

NEG

600 Watts Continuous
1200 Watts Peak

DC Input 10V-15VDC

Up to 60Amps Continuous

AC Output

110V - 120VAC 60Hz
5 Amps Continuous

P/N: 05060

TruePower600