Personal Safety Precautions Continued
5. Be extra cautious to reduce the risk of dropping a metal tool onto a battery. It may
spark or short-circuit the battery or other electrical parts that may cause an explosion.
6. Remove all personal metal items such as rings, bracelets, necklaces, watches and
jewelry when working near a battery. A battery can produce a short circuit high enough
to weld a ring or any metal, causing serious burns.
7. Never charge or invert power from a frozen battery.
*WARNING: Restrictions on Use- The TruePower inverter shall not be used in connection
with life support systems or other medical equipment devices.
Preparing for Installation
Read this entire installation section if you plan a hardwire installation from
beginning to end.
WARNING: This devise is not Ignition Protected
Avoid serious injury or death from or explosion. Do not install in compartments containing
gasoline fueled engines or gasoline tank, or in areas where ignition protected equipment
is required.
WARNING: Do not mount the inverter above or below your batteries.
WARNING: Electrical shock and fire hazards
On Board Solutions, a ProMariner Company recommends all wiring be done by qualified
personnel. Disconnect all AC and DC power sources to prevent accidental shock.
Disable and secure all AC and DC disconnect devices and automatic generator starting
devices. It is the installer’s responsibility to ensure compliance with all the applicable
installation codes and regulations.
WARNING: Installation Precaution
The TruePower inverter should be mounted on a flat horizontal surface or a vertical
surface with the front panel and label facing the user. In no case should the front or
rear endcaps be facing in an upward or downward position. This allows proper ventilation
and product safety of the unit as intended by design.
WARNING: Fire Hazard
Do not cover or obstruct the ventilation openings. Do not install this equipment in a
compartment with limited airflow; Overheating may result.
17
S p e c i f i c a t i o n s
Specifications
TruePower
600W 800W 1000W 1200W
Power (W)
600W
800W 1000W 1200W
Continuous Power
600W
800W 1000W 1200W
Surge Power
1200W 1600W 2000W 2400W
Output Waveform
Modified Sine Wave
AC Output Voltage
115V +/- 10%
AC Output Amps (up to)(continous)
5.5
7.3 9.1 10.9
DC Input Voltage
10V to 15V
DC Input Amps (up to)
60A 80A 100A 120A
Efficiency
>85%
No load Current
<0.65A <0.8A <1.0A <1.0A
Cooling Fan
Yes
Short Protection
Yes
Soft- Start
Yes
High Voltage Protection
Yes
Low Battery Alarm (Bat’ Saver)
11.9VDC
Low Battery Shutdown (Bat’ Saver)
11.5VDC
Low battery Alarm
10.5VDC +/- .5VDC
Low Battery Shutdown
10VDC +/- .5VDC
Reverse Polarity Protection (By Fuse)
Yes
Operating environment temperature
-15 to 50° Celsius or 5 to122° Fahrenheit
Internal Fuse
20A * 4pcs 35A * 3pcs 35A * 4pcs 35A * 4pcs
Recommended User Supplied
80A 105A 140A 140A
ABYC E-11 Compliant Fuse
ProMariner Part No. for
Recommended User Supplied
ABYC E-11 Compliant Fuse
Amperage
100-425 amps 100 amp 100 amp 160 amp 160 amp
ANL Ignition Protected Fuses for TruePower Models
88120 88100 88100 88160 88160
600 Watt 800 Watt 1000 Watt 1200 Watt
Single Position ANL
High Amperage
Fuse Holder