beautypg.com

Specifications, Module characteristics, Table 3-1: absolute maximum ratings – PNI MicroMag User Manual

Page 6: Table 3-2: module operating characteristic, 3 specifications, 1 module characteristics

background image

PNI Sensor Corporation

DOC# 1015175 r01

MicroMag User Manual

– March 2010

Page 6 of 23

3 Specifications

3.1 Module Characteristics

Table 3-1: Absolute Maximum Ratings

Parameter

Symbol

Maximum

Units

DC Supply Voltage

V

DD

5.25

VDC

Input Pin Voltage

V

IN

V

DD

+ 0.3

VDC

Input Pin Current @ 25C

I

IN

10 mA

mA

Storage Temperature

T

STRG

+85

C

CAUTION:

Stresses beyond those listed in Table 3-1 may cause permanent damage to the
device. These are stress ratings only. Functional operation of the device at these or
any other conditions beyond those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.

Table 3-2: Module Operating Characteristic

Parameter

Value

Units

Field Measurement Range

1

-1100 to +1100

T

Gain

2

31.24

counts/ T

Resolution

2

(1/Gain)

0.03

T

Linearity, ± 300 µT

0.6

%

DC Supply Voltage (V

DD

)

3.0 nominal

2.2 to 5.0 allowable

VDC

Idle Current

3

< 0.1

mA rms

Continuous Current

3

0.5

mA rms

Sensor Frequency

3,4

175

kHz

Operating Temperature

-20 to +70

C


Notes:
1) Field Measurement Range is defined as the monotonic region of the output characteristic curve.
2) Period select value of 2048. The Gain and Resolution can be increased by a factor of 2 by

setting the period select to 4095. However, the ASIC counter can overflow if the field is strong
enough to drive the count beyond a signed 16-bit signed integer. Period select set to 2048 is the
highest setting where it is impossible to overflow the counter. In practical magnetometer