beautypg.com

Final installation, Installation, Wiring – Ouellet OVB-HL User Manual

Page 5

background image

4

Final Installation

Figure5

mounting bracket

Figure4

Figure 7

C:Capacitor IR:Infrared lamp IN:Lighting lamp
:Heat protector K: Breaker R:Light H:Heat
F:Exhaust

L

N

M

IN IR IR

C

L

N

K

GND

Light

Exhaust

F

H

R

Heat

Figure6

ventiduct

ceiling

joist

ceiling

outside

wall

ventiduct

Φ4 1/8 inches

cutting Φ4 1/8 inches hole

Figure 1

2. Ducting

Please use required duct material as
specified and required by your local
building codes.

3. Locating the heater

For the purpose of obtaining best heating
effect, from the lamps there should be a 7
feet~ 8 feet overall height to ground.

Note: The ceiling joists must be strong.

A minimum of 2"X7" joists are necessary

for clearance when there is a floor above unit.

4. Remove the fascia

Remove all lamps from the heater. Unclip four fascia-retaining springs inside the housing.
Remove the fascia.

Note: Do not force when removing the infrared lamps.

5. Remove the fascia-retaining spring nearest to the wire cover from housing. Take out

two screws from the wire cover and remove the wire cover (Figure2).

6. Remove one of the knockouts according to the need.

7. Fix a clamp connector or wire holder to the opened

knockout.

a) Position housing between joists and extend mounting brackets. Position brackets so that

bottom edge of housing will be flush with suspended ceiling. Mark the top of keyhole on all four

mounting brackets (Figure4).

b) Remove housing temporarily and pound nails partially into joists at all four marked locations

(Figure5).

c) Hang housing to nails. Pound nails tight.

Note: To ensure a noise-free mount, crimp the bracket channels tightly around mounting

brackets.

3. Fit the in-house end of the duct to the fan outlet of the housing (Figure6).

Keep the duct as straight as possible.

1. Replace the wire cover to the housing.

Figure 2

housing

Wire cover

knockout

Fascia

Heat lamp

Light lamp

INSTALLATION

Figure 3

mounting

bracket

1. Slide adjustable mounting brackets into bracket

channels on housing (Figure 3).

WIRING

1. Put one end of the interconnecting

wire through the opened knockout.

2. Make wire connections with the

terminal block as Figure7.

Note: Make sure that connections are

used to hold wires firmly in place.

3. Connect the other end of

interconnecting wire with the switch

panel (Figure7).

Note:Try to keep the redundant wire

away from the housing.