Installation – Ouellet OVB-HL User Manual
Page 4
3
Dear customers,
Thank you for selecting Aero Pure, which is surely to bring you satisfaction. Read all instructions
before using the heater.
1. Use this heater only as described in this manual. Any other use not recommended by the
manufacturer may cause fire, electric shock, or injury to persons. If you have questions, contact
the manufacture or local agent.
2. Make sure the power is off during the installation. Shut off power before servicing or cleaning.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with
all applicable codes and standards.
4. For the purpose of avoiding any dangerous gas leaking into your bathroom, the duct must not
be laid together with the vent-pipe of air-fueled water heater into the same flue.
5. To prevent a possible fire, do not block air intakes or exhaust in any manner.
6. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may
cause an electric shock or fire, or damage the heater.
7. A heater has hot and arcing or sparking parts inside. Do not use it in area where gasoline,
paint, or flammable liquids are used or stored.
8. The heater must not be installed at a place that suffers from severe water leakage.
9. Do not install closer than 10 inches to a vertical surface and 6 feet to the ground.
10. The heater must not be installed beneath a fixed socket.
11. When cutting into the wall, do not damage electrical wiring and other hidden utilities.
12.The unit has been tested to be in contact with insulation. (Type IC)
13.The heater must be properly grounded.
SAVE THESE INSTRUCTIONS AND READ ALL INSTRUCTIONS
BEFORE USING THE HEATER.
WARNING!
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
CAUTION
PLEASE INSTALL AS THE FOLLOWING STEPS:
14. For supply connections use No. 14 AWG or larger wires suitable for at least 90 (194 ).
15. For overheat protection, exhausting automatically turns on when temperature above the
ceiling exceeds 90 (194 ).
16. The lamps are hot when in use. It is absolutely prohibited to touch the infrared lamps with
any part of your body when in use.
17. Shut off power urgently when any abnormalities occur in operation. Then call your local
licensed electrician for inspection or necessary service work.
18. Children, elders and / or handicapped should use this product under family guidance.
19. Do not use outdoors.
20.To reduce risk of fire, use only type RF lamps 270 watts maximun. Replace bulb with 60
watts type A bulb only. It may affect operation (even cause danger) when use lamps other than
the designated one.
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and
vapors.
2. This product is designed for installation in flat ceilings only. Do not mount it on a sloping
ceiling or a vertical wall.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray,
construction dust, etc. off the unit.
4. It is highly recommended to make preparation for heater installation when you retrofit your
bathroom.
5. Please read specification label on product for further information and requirements.
1. Cutting a vent (Figure1)
Locate a vent position (above the ceiling) on the wall, and then cut a 4 1/8 inches diameter hole
at the very position.
PREPARATION FOR INSTALLATION
INSTALLATION
o
c
o
c
o
c
o
c